yarp-devices
Loading...
Searching...
No Matches
Jr3Mbed_params
Group Parameter Type Units Default Value Required Description Notes
canId int 0 no CAN bus ID 1-127
name string no sensor name
filter double Hz 0.0 no cutoff frequency for low-pass filter 0.0-655.35
ackTimeout double s 0.25 no CAN acknowledge timeout
fullScales vector<int> N, daNm no full scales for each axis 3*N, 3*daNm
asyncPeriod double s 0.0 no period of asynchronous publishing mode 0.0: disabled
monitorPeriod double s 0.1 no monitor thread period
diagnosticsPeriod double s 0.0 no diagnostics period less than 8 seconds